465 research outputs found

    Multimodality treatment of unresectable hepatic metastases from pancreatic glucagonoma

    Get PDF
    Glucagonomas are pancreatic islet cell tumors arising from the alpha cells which belong to neuroendocrine tumors. They frequently metastasize to the liver. We report the case of a 52- year old man with a pancreatic glucagonoma with synchronous multiple liver metastases treated by surgery, transarterial chemoembolization, percutaneous radiofrequency thermal ablation and long-acting octreotide. Our report confirms that a multimodal approach is very effective in patients with unresectable liver metastases from pancreatic endocrine tumors providing long-lasting palliation and probably prolonging survival

    A finite element method model to simulate laser interstitial thermo therapy in anatomical inhomogeneous regions

    Get PDF
    BACKGROUND: Laser Interstitial ThermoTherapy (LITT) is a well established surgical method. The use of LITT is so far limited to homogeneous tissues, e.g. the liver. One of the reasons is the limited capability of existing treatment planning models to calculate accurately the damage zone. The treatment planning in inhomogeneous tissues, especially of regions near main vessels, poses still a challenge. In order to extend the application of LITT to a wider range of anatomical regions new simulation methods are needed. The model described with this article enables efficient simulation for predicting damaged tissue as a basis for a future laser-surgical planning system. Previously we described the dependency of the model on geometry. With the presented paper including two video files we focus on the methodological, physical and mathematical background of the model. METHODS: In contrast to previous simulation attempts, our model is based on finite element method (FEM). We propose the use of LITT, in sensitive areas such as the neck region to treat tumours in lymph node with dimensions of 0.5 cm – 2 cm in diameter near the carotid artery. Our model is based on calculations describing the light distribution using the diffusion approximation of the transport theory; the temperature rise using the bioheat equation, including the effect of microperfusion in tissue to determine the extent of thermal damage; and the dependency of thermal and optical properties on the temperature and the injury. Injury is estimated using a damage integral. To check our model we performed a first in vitro experiment on porcine muscle tissue. RESULTS: We performed the derivation of the geometry from 3D ultrasound data and show for this proposed geometry the energy distribution, the heat elevation, and the damage zone. Further on, we perform a comparison with the in-vitro experiment. The calculation shows an error of 5% in the x-axis parallel to the blood vessel. CONCLUSIONS: The FEM technique proposed can overcome limitations of other methods and enables an efficient simulation for predicting the damage zone induced using LITT. Our calculations show clearly that major vessels would not be damaged. The area/volume of the damaged zone calculated from both simulation and in-vitro experiment fits well and the deviation is small. One of the main reasons for the deviation is the lack of accurate values of the tissue optical properties. In further experiments this needs to be validated

    Stereotactic, single-dose irradiation of stage I non-small cell lung cancer and lung metastases

    Get PDF
    BACKGROUND: We prospectively reviewed response rates, local control, and side effects after non-fractionated stereotactic high single-dose body radiation therapy for lung tumors. METHODS: Fifty-eight patients underwent radiosurgery involving single-dose irradiation. With 25 patients, 31 metastases in the lungs were irradiated; with each of 33 patients, stage I non-small cell lung cancer (NSCLC) was subject to irradiation. The standard dose prescribed to the isocenter was 30 Gy with an axial safety margin of 10 mm and a longitudinal safety margin of 15 mm. The planning target volume (PTV) was defined using three CT scans with reference to the phases of respiration so that the movement span of the clinical target volume (CTV) was enclosed. RESULTS: The volume of the metastases (CTV) varied from 2.8 to 55.8 cm(3 )(median: 6.0 cm(3)) and the PTV varied from 12.2 to 184.0 cm(3 )(median: 45.0 cm(3)). The metastases ranged from 0.7 to 4.5 cm in largest diameter. The volume of the bronchial carcinomas varied from 4.2 to 125.4 cm(3)(median: 17.5 cm(3)) and the PTV from 15.6 to 387.3 cm(3 )(median: 99.8 cm(3)). The bronchial carcinomas ranged from 1.7 to 10 cm in largest diameter. Follow-up periods varied from 6.8 to 63 months (median: 22 months for metastases and 18 months for NSCLC). Local control was achieved with 94% of NSCLC and 87% of metastases. No serious symptomatic side effects were observed. According to the Kaplan-Meier method the overall survival probability rates of patients with lung metastases were as follows: 1 year: 97%, 2 years: 73%, 3 years: 42%, 4 years: 42%, 5 years: 42% (median survival: 26 months); of those with NSCLC: 1 year: 83%, 2 years: 63%, 3 years: 53%, 4 years: 39%: (median survival: 20.4 months). CONCLUSION: Non-fractionated single-dose irradiation of metastases in the lungs or of small, peripheral bronchial carcinomas is an effective and safe form of local treatment and might become a viable alternative to invasive techniques

    CT-guided intratumoural administration of cisplatin/epinephrine gel for treatment of malignant liver tumours

    Get PDF
    To analyze prospectively the interventional and clinical aspects of computed tomography-guided direct intratumoural injection of a novel chemotherapeutic administration and the parenchymal changes of tumour and necrosis in malignant liver tumours. Eight patients with 17 colorectal liver metastases were treated with a mean of 5.1 injections and nine patients with 13 hepatocellular carcinoma nodules with a mean of 3.1 treatments with computed tomography guided local applications of a novel cisplatin/epinephrine gel. This application provides a higher local and lower systemic drug concentration. Volumes of tumour and necrosis prior and after treatment were measured by computer generated volumetric analysis. Contrast enhanced studies verified pretherapeutic viable tumour volumes with a value of 77.4 ml in the metastases and 29.2 ml in the hepatocellular carcinoma nodules. Intratumoural drug application resulted in a significant increase of necrosis and a decrease in viable tumour volume to be 68.3 ml in metastases and 14.5 ml in hepatocellular carcinoma. Local therapy control rate for the follow up to 6 months was 38 and 71% for the group of metastases and hepatocellular carcinoma, respectively. Direct intratumoural injection of cisplatin/epinepthrine injectable gel is a feasible and good tolerated method and results in the development of a statistically significant increase in necrosis in malignant liver tumours. For hepatocellular carcinoma a higher local therapy control rate compared to colorectal metastases can be reported

    Percutaneous vertebral compression fracture management with polyethylene mesh-contained morcelized allograft bone

    Get PDF
    Study design    A comprehensive systematic review of the literature. Objectives To assess the modern literature on the use of polyethylene mesh-contained morcelized allograft (PMCMA) bone for spinal fusion and vertebral compression fracture management. Summary of background data    There are presently no systematic reviews of PMCMA. Methods    A systematic literature review was performed within three databases (OVID, PubMed, and Google Scholar) using the following keyword search terms: vertebroplasty, kyphoplasty, vertebral compression fracture, percutaneous, polyethylene mesh, and osteoporosis. Results    The initial search identified 764 items, from which two pertinent technique-based articles were identified. There were no published scientific peer-reviewed or case series reporting the clinical results of this technique. The use of PMCMA in the management of vertebral compression fractures (VCFs) is similar to vertebroplasty and kyphoplasty. This novel, percutaneous system uses the properties of granular mechanics to establish a conforming, semirigid graft that is purportedly capable of withstanding physiologic loads. Discussion    PMCMA is a novel percutaneous technology for the management of VCF and possibly for use as a conforming interbody graft. The available published literature lacks outcome data of the use of PMCMA. Careful, independent research is needed to assess the viability of this technology and its long-term results

    Severe gastric variceal haemorrhage due to splenic artery thrombosis and consecutive arterial bypass

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Upper gastrointestinal haemorrhage is mainly caused by ulcers. Gastric varicosis due to portal hypertension can also be held responsible for upper gastrointestinal bleeding. Portal hypertension causes the development of a collateral circulation from the portal to the caval venous system resulting in development of oesophageal and gastric fundus varices. Those may also be held responsible for upper gastrointestinal haemorrhage.</p> <p>Case presentation</p> <p>In this study, we describe the case of a 69-year-old male with recurrent severe upper gastrointestinal bleeding caused by arterial submucosal collaterals due to idiopathic splenic artery thrombosis. The diagnosis was secured using endoscopic duplex ultrasound and angiography. The patient was successfully treated with a laparoscopic splenectomy and complete dissection of the short gastric arteries, resulting in the collapse of the submucosal arteries in the gastric wall. Follow-up gastroscopy was performed on the 12<sup>th </sup>postoperative week and showed no signs of bleeding and a significant reduction in the arterial blood flow within the gastric wall. Subsequent follow-up after 6 months also showed no further gastrointestinal bleeding as well as subjective good quality of life for the patient.</p> <p>Conclusion</p> <p>Submucosal arterial collaterals must be excluded by endosonography via endoscopy in case of recurrent upper gastrointestinal bleeding. Laparoscopic splenectomy provides adequate treatment in preventing any recurrent bleeding, if gastric arterial collaterals are caused by splenic artery thrombosis.</p

    The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population

    Get PDF
    High-intensity focused ultrasound (HIFU) provides a potential noninvasive alternative to conventional therapies. We report our preliminary experience from clinical trials designed to evaluate the safety and feasibility of a novel, extracorporeal HIFU device for the treatment of liver and kidney tumours in a Western population. The extracorporeal, ultrasound-guided Model-JC Tumor Therapy System (HAIFUℱ Technology Company, China) has been used to treat 30 patients according to four trial protocols. Patients with hepatic or renal tumours underwent a single therapeutic HIFU session under general anaesthesia. Magnetic resonance imaging 12 days after treatment provided assessment of response. The patients were subdivided into those followed up with further imaging alone or those undergoing surgical resection of their tumours, which enabled both radiological and histological assessment. HIFU exposure resulted in discrete zones of ablation in 25 of 27 evaluable patients (93%). Ablation of liver tumours was achieved more consistently than for kidney tumours (100 vs 67%, assessed radiologically). The adverse event profile was favourable when compared to more invasive techniques. HIFU treatment of liver and kidney tumours in a Western population is both safe and feasible. These findings have significant implications for future noninvasive image-guided tumour ablation
    • 

    corecore